The article aims at developing simple, fast and effective dissolution method for Dabigatran etexilate mesylate capsules by RP-HPLC and validate as per ICH guidelines. The optimized RP-HPLC method for dissolution studies uses a reverse phase column, Phenomenex Luna C18 (250 X 4.6 mm;5μ), a mobile phase of triethylammonium phosphate buffer (pH 3.0):acetonitrile in the proportion of 40:60 v/v, diluent as 0.01N HCl, flow rate of 1.0ml/min, injection volume as 20µl. and a detection wavelength of 341nm using a UV detector. The optimized dissolution conditions include, 0.01N HCl as dissolution media, apparatus as USP Type 1 Basket, rpm as 100, dissolution media temperature as 37±0.5ºC, dissolution volume as 500ml, dissolution time point as 30mts, working concentration of standard and sample as 5µg/ml and a detection wavelength of 341 nm. The developed method resulted in Dabigatran etexilate exhibiting linearity in the range 1.25-10μg/ml. System precision and intra-day precision is exemplified by relative standard deviation of 1.59% and 2.21% respectively. Method was found to be rugged/inter day precise as %RSD was found to be 3.25. Percentage Mean recovery was found to be greater than 80% at all the three levels by absolute method during accuracy studies. LOD and LOQ for Dabigatran etexilate were found to be 0.05ng/ml and 5ng/ml respectively. Hence it can be concluded that effective dissolution method by RP-HPLC is developed and validated as per ICH guidelines which can be applicable in various pharmaceutical industries.

Keywords: Dabigatran etexilate, Dissolution, RP-HPLC, ICH guidelines, Validation


[PDF]  Viewed: 606  Downloaded: 130
  • Call for paper

    American Journal of PharmTech Research (AJPTR) is a peer-reviewed, bimonthly official international journal allowing access to abstracts and full-text.

    Read more...

     

  • Email & SMS Alerts

    Email/SMS alert system is one of the key features and gives update information about the submitted manuscript.

    Read more...

  • Article Statastics

    American Journal of PharmTech Research (AJPTR) provides unique facility for authors to know popularity of articles on basis of numbers of PDF download and views. It will display in tabulated format.

  • Online Submission

    American Journal of PharmTech Research (AJPTR) is one of the International open access journal devoted to various disciplines in science and technology.

    Read more...

web counter
web counter